Sahajanand Laser Technology Limited
Sahajanand Laser Technology Limited
Gandhinagar, Gujarat
GST No. 24AAGCS1983B1ZK
TrustSEAL Verified
Call 08048969058 87% Response Rate
SEND EMAIL

Drug Eluting Coronary Stent

Drug-eluting stents (DES) are a standard metallic tubular mesh like medical device with a an anti-proliferative drug blended within a biodegradable polymers, which allows drug elution into the coronary wall for weeks to monthsafter stent implantation and prevent the growth of scar tissue in the artery lining. This helps the artery remain open, ensuring good blood flow and reduces the chances of the artery re-narrowing or restenosis. SLTL’s Drug eluting stent gives confidence to interventional cardiologists for their safety and efficacy over the years.

EverPro - Drug Eluting Coronary Stent - SLTL Medical

EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
  • EverPro - Drug Eluting Coronary Stent - SLTL Medical
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Stent DesignHybrid
BrandSLTL Medical
Model Name/NumberEVERPRO
Country of OriginMade in India
Attribute 1The Electro-Polishing
Attribute 2The Laser Cutting
Attribute 3The Drug Coating

* Sahajanand Laser Technology Ltd. reserves the right to make changes at any time without prior notice or notification

 

** The price is not final; please consult with the SLTL team for the final price.




The Schifsorb Polymer Technology


It takes something extraordinary to stand apart and overcome any hurdle. SLTL incorporated the advanced Schifsorb Polymer Technology. This revolutionary technology by SLTL pairs the power of biodegradable PLLA and PLGA polymers with an Integrated Everolimus drug. The Schifsorb polymer technology of the EverPro delivers a dynamic performance along with great drug release efficiency. The thrombus-resistant polymer degrades with minimal tissue inflammation, which truly underplays risk of stent thrombosis.

 

Key Features

The Drug Coating

The Conformal Coating Of Everolimus At A Dose Of 1.1 µg/Mm² Provides Optimum Anti-Proliferation And Endothelial Regeneration, Which In-Turn Assist To Reduce Re-Stenosis.

The Electro-Polishing     

The Status-Quo Electro-Polishing Process Provides Ultra Smooth Stent Surface, Reduces Risk Of Edge Dissection And Very Late Stent Thrombosis.

The Laser Cutting             

A Bold Stance And Elegant Curves With Highly Accurate Fiber Laser Machine Provides Dimension Accuracy Of 2 µ, Which Makes Everpro Stand Apart.

The Stent Design

With U.S. Patented Alternate "C" And "S" Links Are What Make Everpro Stand Apart, It Blends Sophistication With A Design Philosophy That Is Bold And Unparalleled. Finely Engineered Elements Of An Expansive Cobalt Chromium L605 Platform, Enhances Stent Flexibility.

An Ideal Stent Material   

The Cobalt Chromium L605 Metal Alloy Is A Proven Stent Platform In Several Clinical Trials For Its Strength And Compatibility.

 

* Price depends on required configurations.

Request
Callback


Additional Information:

  • Item Code: EverPro
Yes! I am Interested

FlexyRap - Drug Eluting Coronary Stent - SLTL Medical

FlexyRap - Drug Eluting Coronary Stent - SLTL Medical
  • FlexyRap - Drug Eluting Coronary Stent - SLTL Medical
  • FlexyRap - Drug Eluting Coronary Stent - SLTL Medical
  • FlexyRap - Drug Eluting Coronary Stent - SLTL Medical
  • FlexyRap - Drug Eluting Coronary Stent - SLTL Medical
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Stent DesignHybrid
BrandSLTL Medical
Model Name/NumberFlexyRap
Country of OriginMade in India
Attribute 1Semi Open (Hybrid) U.S. Patented Stent Design
Attribute 2Biodegredable Polymer with excellent biocompatibility
Attribute 3Sustained Rapamycin (Sirolimus) release over 28 days for therapeutic efficacy.

* Sahajanand Laser Technology Ltd. reserves the right to make changes at any time without prior notice or notification

 

** The price is not final; please consult with the SLTL team for the final price.


Cobalt Chromium Rapamycin-Eluting Coronary Stent System (From Biodegradable Polymer Matrix)

FlexyRap has a coating which undergoes complete biodegradation of polymer within 7 to 9 months FlexyRap has drug /polymer coating of a 5-6 micron which gives excellent deliverability to follow vessel motion which ensures conformability. The growth of 8% from Nominal pressure to RBP allows complete development and good wall apposition. Flexyrap is a Biodegradable polymer with biocompatibility. Engineered with unparallel flexibility with the pivoted articulation design it ensures good trackability, crossability & conformability.

 

Key Features

  • Biodegradable Polymer with excellent biocompatibility
  • Sustained Rapamycin (Sirolimus) release over 28 days for therapeutic efficacy.
  • Semi Open (Hybrid) U.S. Patented Stent Design.
  • Drug : Rapamycin (Sirolimus) Dose: 1μg/mm²
  • Superior Stent mechanics through strong cobalt chromium alloy.
  • Better fatigue and corrosion resistance performance.
  • Coating thickness less than 6μ
  • Growth of 8% from nominal pressure to RBP allowing complete deployment and good wall apposition.
  • Ultra-smooth Electropolished finishing.


* Final price depends on required configurations.

Request
Callback


Additional Information:

  • Item Code: FlexyRap
Yes! I am Interested

NeoHexa - Drug Eluting Coronary Stent - SLTL Medical

NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
  • NeoHexa - Drug Eluting Coronary Stent - SLTL Medical
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity1 Piece
Stent DesignHybrid
BrandSLTL Medical
Model Name/NumberNeoHexa
Country of OriginMade in India
Attribute 1Low recoil ensures predictable results
Attribute 2Low deflation time
Attribute 3Excellent & uniform scaffolding

* Sahajanand Laser Technology Ltd. reserves the right to make changes at any time without prior notice or notification

 

** The price is not final; please consult with the SLTL team for the final price.


Neohexa is a Sirolimus Eluting Cobalt Chromium Coronary Stent with unique proprietary Biodegradable polymer matrix which gives excellent coating integrity.

Neo Hexa is designed in a manner that it maintains metal artery ratio. The design of a stent is innovative with ‘S’ link and alternate ‘C’ link. In Cobalt Chromium stent we use Sirolimus drug because Sirolimus /Rapamycin is a Potent anti-proliferative agent when coated on coronary stents it prevents organ re-stenosis.

With the features of Excellent and Uniform Scaffolding these devices provides short-term scaffolding of the vessel and then dissolve, which should theoretically circumvent the side effects of metal drug-eluting stent. High radial strength which makes it ideal for proximal lesion. Minimal Balloon overhang which minimize risk of edge dissection (a procedural complication of percutaneous coronary interventions.)


Highlights

  • Minimal Balloon Overhang which minimizes the risk of edge dissection
  • A high radial strength which makes it ideal for proximal lesion
  • Low recoil ensures predictable results
  • Low deflation time
  • Excellent & uniform scaffolding
  • No Foreshortening suitable for Ostial lesion

Key Features

  • 8 crowns for uniform & optimum vessel scaffolding
  • Customized crown length for 2.25, 2.50, 2.75, 3.0, 3.5, & 4.0 mm
  • Maintain consistent metal-artery ratio
  • Innovative “S” link and alternate “C” link design
  • Superior stent strength through strong cobalt chromium alloy
  • Thin Strut (60 µm)
  • Drug : Sirolimus 1.0 µg/mm²
  • Thin drug/polymer coating thickness: 4-5 micron
  • Excellent deliverability & conformability
  • Growth of 8 % from nominal pressure to RBP allowing complete deployment and good wall apposition
  • Available in length up to 48 mm


* Final price depends on required configurations.

Request
Callback


Additional Information:

  • Item Code: NeoHexa
Yes! I am Interested
X

Product Videos

Watch More Videos

Explore More Products

View All Products
Tell Us What Are You Looking For ?




Reach Us
Alex (Customer Relationship Manager)
Sahajanand Laser Technology Limited
E-30,Electronics, Estate Gidc, Gandhinagar - 382028, Gujarat, India
Get Directions

Call Us


Send E-mail